Our Thermic Fluid Heaters deliver reliable, efficient heating for various industrial processes. With advanced technology, they ensure precise temperature control and energy efficiency, making them ideal for demanding applications.
| Heat Load | LKcal/hr | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 15 | 20 | 25 |
| Max. Fluid Outlet Temp | Deg C | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 | 280 |
| Flow rate | m 3/hr | 9 | 18 | 27 | 29 | 36 | 43 | 57 | 71 | 86 | 107 | 142 | 178 |
| Temp Difference | Deg C | 25 | 25 | 25 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 |
| Efficiency | % | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 | 87±2 |
| Pressure Drop | Kg/Cm 2 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 | 2 to 3 |
| Heat Transfer area (TFH) | M2 | 9 | 14 | 19 | 27 | 33 | 39 | 52 | 65 | 78 | 98 | 130 | 163 |
| Expansion Tank Capacity | Ltrs. | 250 | 500 | 500 | 750 | 750 | 750 | 1250 | 1500 | 1500 | 2000 | 2500 | 3000 |
| Length | m | 2.5 | 2.5 | 3.5 | 4.5 | 5 | 5 | 6 | 6 | 6.5 | 7 | 7.5 | 8 |
| Width | m | 2.2 | 2.2 | 2.2 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3.5 | 4 |
| Height | m | 2.5 | 2.5 | 2.5 | 3 | 3.5 | 3.5 | 5 | 5 | 5 | 5.5 | 5.5 | 5.5 |
| Diesel on NCV 10500 Kcal/Ltrs. | Ltrs./hr | 11 | 22 | 33 | 44 | 55 | 66 | 88 | 109 | 131 | 164 | 219 | 274 |
| FO on NCV 9650 Kcal/Kg | Kg/hr | 12 | 24 | 36 | 48 | 60 | 71 | 95 | 119 | 143 | 179 | 238 | 298 |
| N.Gas on NCV 8600 Kcal/Nm3 | Nm3/hr | 13 | 27 | 40 | 53 | 67 | 80 | 107 | 134 | 160 | 200 | 267 | 334 |
| Pellet on GCV 4200 Kcal/Nm3 | Nm3/hr | 26 | 53 | 78 | 104 | 129 | 155 | 207 | 259 | 311 | 388 | 518 | _ |